Mobile Xray C Arm Radiology Equipment Portable Fluoroscopy Machine

Product Details

Place of Origin: CHINA

Brand Name: VOLITION

Certification: ISO13485、FSC

Model Number: Picke 2200DRF

Document: Product Brochure PDF

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: Negotiable

Packaging Details: Standard Exportation Package

Delivery Time: 7-15 work days

Payment Terms: LC, T/T, D/P, PayPal, Western Union

Chat now
Highlight:

Xray c arm radiology equipment

,

Fluoroscopy c arm radiology equipment

,

Mobile Xray portable fluoroscopy machine

Type:
Mobile C-arm
Power Supply:
110V/220V
Output Power:
50kw High Frequency Generator
X-ray Tube:
Cannon
Detector Type:
Dynamic FPD
Detector Size:
10''x 10''
DAP:
YES
Color:
White
Mobile Rack:
Integrated
Type:
Mobile C-arm
Power Supply:
110V/220V
Output Power:
50kw High Frequency Generator
X-ray Tube:
Cannon
Detector Type:
Dynamic FPD
Detector Size:
10''x 10''
DAP:
YES
Color:
White
Mobile Rack:
Integrated
Mobile Xray C Arm Radiology Equipment Portable Fluoroscopy Machine
Simple structure, highly integrated, no external drag cable, easy to use;
 
Large anode heat capacity to support long-term use;
 
High Ma pulse does not worry about the unclear body position image of obesity;
 
Excellent image algorithm without dynamic tailing;
 
AK & AKR dynamic monitoring; Real time dose display; High dose prompt; Over dose suspension exposure;
 
50KW high power.

 

  Part Model Main technical parameters and performance description
1

 

High voltage generator

 

DTXR-50HF

Power: 50KW;

Photograph tube current: 10mA~630mA; continuous fluoroscopy tube current: 0.5mA~6mA; pulse fluoroscopy tube current: 1mA~ 80mA;

Exposure current time product 0.1mAs~ 630mAs;

Photograph tube voltage:40kV~150kV; fluoroscopy tube voltage 40kV~125kV;

can be directly connected to the network cable and remote control for fault judgment and maintenance.

2

 

X ray tube

 

E7884X

Dual focus 0.6mm/1.2mm; power 20 / 50KW; maximum current 700mA; maximum photography voltage 150kV; maximum fluoroscopy voltage 125kV; target angle 12°: permanent filtration 0.9 mm Al / 75KV;

anode heat capacity 210KJ(300khu).

3 High voltage cable 75KV-3M

Withstand voltage: 75KV;

Length: 3m.

4 Mobile C-arm rack

CZJ

The sliding angle of C-arm along the arc track of arm support is 110°;

The rotation angle of C-arm along the horizontal axis is ± 180°;

The range of C-arm moving up and down along the vertical direction is 350mm;

Sid: 1000mm;

Maximum vertical depth from X-ray center to arc wall of C-arm: 500mm; Minimum distance from X-ray source assembly shell to image receiver: 800mm;

Mobile performance:

  • The braking force of the C-arm on the flat cement ground is not less than 200N;
  • The starting push (pull) force is not more than 250N while the C-arm is on the flat cement ground.
  • Sports protection:Mechanical foot brake.
5 Flat Panel Detector

CareView

560RF

Caesium iodide amorphous silicon panel;

Pixel matrix: 1536x1536pixels;

Imaging area: 236mmx236mm;

Pixel size: 154μm; spatial resolution: 3.3lp/mm; AD conversion 16bits; Maximum frame rate in various photography modes:13fps@1536 × 1536pixels , 30 fps@768 × 768pixels;

Dynamic range: > 80dB;

Imaging time: photography imaging time is not more than 5s, fluoroscopy imaging time is not more than 1s.

6

Image

acquisition

workstation

 

PICKE-DRF

 

DICOM3.0 standard; the reference exposure parameters of each position can be directly called out from the software for doctors to adjust the exposure parameters of the high voltage generator panel for

Reference;

Digital photography function, configurable positive and negative image acquisition;

Digital real-time fluoroscopy function: real-time automatic window width and window level adjustment; real-time edge enhancement: flip and rotate according to different positions; display patient information /

examination information / settings Standby information / image information; real time prompt the number of images that the system can store;real time automatic ROI clipping.

Under the highest pulse fluoroscopy frame rate, fluoroscopy: image stability time is not more than 2s; automatic fluoroscopy function, image

brightness stability is not more than 15%; photography under the maximum field of vision: 75KV, 80mA,5mAs, the number of discernible dynamic wedges is not less than 16;

Under the maximum field of vision fluoroscopy: 50kV, 3mA, discernable dynamic order wedge number is not less than 15; the maximum fluoroscopy image acquisition rate should not be less than 25 frames / s.

Hardware configuration:

CPU: i5-7500 or above; Memory: 4G or above;

Graphics card: GPU NVIDIA Geforce GTX 750ti / p620 (GPU computing power above 5.0)

Hard disk: 1 T;

Motherboard: 1 graphics card slot 1 pci- exi6 / pci-ex4 or gigabit network card;

Operating Display: 1600 * 1200 resolution;

System software: windows7, windows10 (64 bit)

7 Grid

10*10

The grating ratio is 10:1; 40lp / cm; the size is 25 * 25cm.
8 Collimator XSQ-C Fixed type
9 Dose monitoring device   DAP; AK; AKR dynamic monitoring; real-time display; high dose prompt; over dose termination of exposure.
10 Documents   Registration certificate, document, instruction manual, product certificate.

 